0x2e112008 The ONT works in emergency channel mode
0x2e112008 The ONT works in emergency channel mode:
Today i will discuss about 0x2e112008 The ONT works in emergency channel mode alarm. System generates 0x2e112008 The ONT works in emergency channel mode alarm, when the ONT software works in the emergency channel mode.
Attribute:
Alarm ID | Alarm Severity | Alarm Type |
---|---|---|
0x2e112008 | Major | Fault |
Impact on the System:
The ONT software is abnormal and the services on the ONT are interrupted
Possible Causes:
- The ONT software version is too early.
- The ONT is abnormal.
Procedure:
- Upgrade the ONT software. Then, check whether the system generates the clear alarm.
- Reset or replace the ONT. Then, check whether the system generates the clear alarm.

0x2e112008 The ONT works emergency channel mode
Related clear alarm: 0x2e122008 The work mode of the ONT recovers
0x2e112008 The ONT works in emergency channel mode was last modified: January 10th, 2016 by