September 11, 2025

TR-069 Basic Fundamental

TR-069 Basic Fundamental Today i will discuss about TR-069 Basic Fundamental. Bellow are the details FAQ and it’s answer. [boxads] What is TR-069? The CWMP stands for CPE WAN Management Protocol, it published by The Broadband Forum as TR-069, specifies a standard communication mechanism for the remote management of end-user devices. It defines a protocol for the secure auto-configuration of a TR-069 device and incorporates other management functions into a common framework. This protocol simplifies device management by specifying the use of an auto configuration server (ACS) to perform remote, centralized management of customer premises equipment (CPE). Who created TR-069 …

TR-069 Basic Fundamental Read More

Remote optical transceiver parameters exceed alarm threshold

0x2e31305e Remote optical transceiver parameters exceed alarm threshold System generates 0x2e31305e Remote optical transceiver parameters exceed alarm threshold alarm. When the values of the parameters configured for the optical transceiver on the ONT side exceed the alarm thresholds. [boxads] Attribute: Alarm ID Alarm Severity Alarm Type 0x2e31305e Minor Fault Impact on the System: The system cannot work normally, for example, the ONT goes online and offline abnormally and packets are lost. Possible Causes: The ONT’s optical transceiver is faulty. The voltage is abnormal. The current is abnormal. The temperature is abnormal. The alarm thresholds set in the system are improper. …

Remote optical transceiver parameters exceed alarm threshold Read More

Local optical transceiver parameters exceed alarm threshold

0x2e31305c Local optical transceiver parameters exceed alarm threshold System generates 0x2e31305c Local optical transceiver parameters exceed alarm threshold alarm. When the values of the parameters configured for the optical transceiver on the OLT side exceed the alarm thresholds. [boxads] Attribute: Alarm ID Alarm Severity Alarm Type 0x2e31305c Major Fault Impact on the System: The system cannot work normally, for example, the ONT goes online and offline abnormally and packets are lost. Possible Causes: The OLT’s optical transceiver is faulty. The alarm thresholds set in the system are improper. Procedure: Run the display port state command to query the transmit optical …

Local optical transceiver parameters exceed alarm threshold Read More

Physical equipment error of ONTi (PEEi) occurs

physical equipment error of ONTi (PEEi) occurs The physical equipment error (PEE) message is a type of PLOAM message. System generates 0x2e11a00f The physical equipment error of ONTi (PEEi) occurs alarm When the ONT can not send the GEM frame and the OMCI message frame, the PEE message is generated. After receiving the PEE message, the system is informed that the physical equipment of the ONT is faulty. [boxads] Attribute: Alarm ID Alarm Severity Alarm Type 0x2e11a00f Warning Fault Impact on the System: The ONT fails; therefore, the data cannot be forwarded, and the services of the ONT are interrupted. …

Physical equipment error of ONTi (PEEi) occurs Read More

PLOAM of ONTi occurs(LOAMi/LOPCi)

0x2e11a00c The loss of PLOAM of ONTi occurs(LOAMi/LOPCi) Today i will discuss about (LOAMi/LOPCi) Alarm. System generates 0x2e11a00c The loss of PLOAM of ONTi occurs(LOAMi/LOPCi) alarm, after the OLT requires the ONT to transmit the PLOAMU message, the ONT goes offline if the OLT does not receive the PLOAM message from the ONT for multiple consecutive times. [boxads] Attribute: Alarm ID Alarm Severity Alarm Type 0x2e11a00c Warning Fault Impact on the System: The ONT fails to work in the normal state, and the ONT goes offline. Possible Causes: The quality of the optical path is poor. The ONT is abnormal. …

PLOAM of ONTi occurs(LOAMi/LOPCi) Read More

PLOAM message with ONTi (LOAi) occurs

0x2e11a00a The loss of acknowledgement PLOAM message with ONTi (LOAi) occurs Today i will discuss about 0x2e11a00a The loss of acknowledgement PLOAM message with ONTi (LOAi) occurs alarm. System generates this alarm When the OLT issues the PLOAM message that requires the ONT to confirm, but the ONT does not respond. [boxads] Attribute: Alarm ID Alarm Severity Alarm Type 0x2e11a00a Warning Fault Impact on the System: The ONT fails to go online. Possible Causes: The quality of the optical path is poor. The ONT is abnormal. Procedure: Check the optical fiber. If the optical fiber is not connected properly, reconnect …

PLOAM message with ONTi (LOAi) occurs Read More
error: Content is protected !!