Physical equipment error of ONTi (PEEi) occurs

physical equipment error of ONTi (PEEi) occurs

The physical equipment error (PEE) message is a type of PLOAM message. System generates 0x2e11a00f The physical equipment error of ONTi (PEEi) occurs alarm When the ONT can not send the GEM frame and the OMCI message frame, the PEE message is generated. After receiving the PEE message, the system is informed that the physical equipment of the ONT is faulty.

[boxads]

Attribute:

Alarm ID Alarm Severity Alarm Type
0x2e11a00f Warning Fault

Impact on the System:

The ONT fails; therefore, the data cannot be forwarded, and the services of the ONT are interrupted.

Possible Causes:

The ONT is abnormal.

Procedure:

  1. Reset or replace the ONT manually.

[bodyads]

Physical layer OAM (PLOAM) is an OAM protocol at the physical layer, used for implementing the OAM function between the ONT and the OLT.

Related clear alarm: 0x2e12a00f The physical equipment error of ONTi (PEEi) recovers

0x2e11a00f The physical equipment error of ONTi (PEEi) occurs
0x2e11a00f The physical equipment error of ONTi (PEEi) occurs
Shahed Israr

Shahed Israr

Shahed Israr is a Network Engineer specializing in GPON, FTTH, and telecom access network technologies. With hands-on experience in Huawei OLT and ONT configuration, U2000 NMS deployment, iMaster NCE-FAN Lite management systems, firmware upgrades, and advanced network troubleshooting, he helps Internet Service Providers (ISPs) and network professionals deploy, manage, and optimize fiber optic networks efficiently. Through GPON Solution, he shares practical technical guides, real-world solutions, and professional knowledge to support engineers working in modern GPON infrastructure.

More Posts - Website

Follow Me:Add me on XAdd me on FacebookAdd me on LinkedInAdd me on PinterestAdd me on YouTubeAdd me on Reddit

Comments

comments

Leave a Comment

Time limit is exhausted. Please reload CAPTCHA.