UAPs Uplink master slave port configure ZTE OLT
[boxads]
Today i will be discuss how to UAPs Uplink master slave port configure ZTE OLT
Prerequisites:
- Make sure that the network device works normally.
- Uplink ports work normally.
- Log in to the ZXA10 C220 through HyperTerminal or Telnet.
Context:
ZXA10 C220 supports UAPS. When the working uplink port is faulty, the service is switched to the backup uplink port automatically.
To configure the UAPS, perform the following steps:
1. Use the configure terminal command to enter global configuration mode.
2. Use the uaps-group command to configure UAPS group.
3. Use the port command to configure main and backup ports of UAPS group.
4. Use the revertive enable command to enable UAPS auto-recovery function.
5. Use the swap command to swap UAPS master and slave ports by force.
6. Use the switch command to configure UAPS group properties.
7. Use the next-hop command to configure UAPS next hop IP address of link detection.
8. Use the retry-link-detect command to configure UAPS retry times of link detection.
9. Use the interval-link-detect command to configure UAPS interval of link detection.
10. Use the show uaps groupid command to query UAPS configuration.