November 15, 2024

MA5801 OLT Board info

MA5801 OLT Board info:

The MA5801 OLT is an integrated OLT. Its universal interface board, control board, service board, and upstream interface board are software virtualized modules, and its subrack ID, slot ID, and port ID are defined by software. For detailed definitions, see the following table.

Service Subrack

Range of Subrack ID

MA5801

0

Subrack Model

Control Board

Service Board

Upstream Interface Board

Universal Interface Board

Power Board

Name

Slot ID

Name

Slot ID

Name

Slot ID

Name

Slot ID

Name

Slot ID

MA5801-GP16

V921MPCC

3

V921GPHF

1

V923NXHC

2

V921CIUA

0

DC: PDC300S12

AC: PAC300S12

4, 5

MA5801-FL16-H1 V921MPCB 3 V921FLHF 1 V921NXHC 2 V921CIUA 0

DC: PDC300S12

AC: PAC300S12

4, 5
MA5801-GP16-H2 V922MPCC 3 V922GPHF 1 V925NXHC 2 V921CIUA 0

DC: PDC300S12

AC: PAC300S12

4, 5
MA5801-GP08-H2 V921MPCC 3 V921GPHD 1 V923NXHC 2 V921CIUA 0

DC: PDC300S12

AC: PAC300S12

4, 5

MA5801-GP08-H3

V922MPCC

3

V922GPHD

1

V925NXHC

2

V921CIUA

0

DC: PDC300S12

AC: PAC300S12

4, 5

MA5801-GP16:

MA5801-GP16

 

 

 

 

MA5801-FL16-H1:

MA5801-FL16-H1

MA5801-GP16-H2:

MA5801-GP16-H2

MA5801-GP08-H2:

MA5801-GP08-H2

MA5801-GP08-H3:

 

MA5801 OLT Primary Features

Layer 2 features
VLAN+MAC forwarding SVLAN+CVLAN forwarding
PPPoE+ DHCP option82
Layer 3 features
Static route RIP/RIPng
OSPF/OSPFv3 IS-IS
BGP/BGP4+ ARP
DHCP relay VRF
Multicast
IGMP v2/v3 IGMP Proxy/Snooping
MLD v1/v2 MLD Proxy/Snooping
VLAN-based IPTV multicast IPv4 PIM and PIM-SSM
QoS
Traffic classification Priority processing
trTCM-based traffic policing WRED
Traffic shaping HQoS
PQ/WRR/PQ+WRR ACL
IPv6
IPv4/IPv6 dual stack IPv6 L2 and L3 forwarding
DHCPv6 relay
System reliability
GPON Type B/Type C protection ERPS (G.8032)
2 power boards for redundancy protection In-service board fault detection and rectification
Aggregation
Aggregation management

Indicator on The Panel Indicators

Indicator Name Color Status Description
RUN/ALM Running status indicator Green Blinking slowly (on for 1s and off for 1s repeatedly) The board functions properly.
Green Blinking quickly (on for 0.25s and off for 0.25s repeatedly) Indicates that program loading is in progress.
Orange Blinking A high-temperature alarm is generated.
Red On The board is faulty.
Red Blinking (on for 0.25s and off for 0.25s repeatedly) The board is starting.
CRI Alarm indicators Red On The system has generated a critical alarm.
MAJ Alarm indicators Orange On The system has generated a major alarm.
MIN Alarm indicators Yellow On The system has generated a minor alarm.
PON 0–15 Link/data status indicator Green On The ONT connected to the related PON port is online.
Green Blinking The optical module does not take effect.
Off The ONT connected to the related PON port is not offline.

Indicator on The Upstream Port

Ports Indicator Name Color Status Description
Upstream optical port LINK Link status indicator Green On A connection is set up on the port.
Off No connection is set up on the port.
ACT Data status indicator Yellow Blinking Data is being transmitted.
Off No data is being transmitted.

Indicator on DC Power

Indicator Name Color Status Description
STAT Power indicator Green On The input/output is normal.
Green Blinking The power supply is in hiccup protection mode.
Off The power input is abnormal (no input, input overvoltage or undervoltage), and the power output is abnormal (undervoltage, overvoltage, or short circuit).

Indicator on AC Power

Indicator Name Color Status Description
STAT Power indicator Green On The input/output is normal.
Green Blinking The power supply is in hiccup protection mode.
Off The power input is abnormal (no input, input overvoltage or undervoltage), and the power output is abnormal (undervoltage, overvoltage, or short circuit).

Indicator on Fan

Indicator Color Status Meaning Operation Description
STATUS Yellow Blinking (on for 0.25s and off for 0.25s repeatedly) The fan module is not registered. If the fan module is not registered, no action is required.
Green Blinking (on for 1s and off for 1s repeatedly) The fan module works in the normal state. No action is required.
Red Blinking (on for 0.25s and off for 0.25s repeatedly) The fan module is faulty. Replace the faulty fan module.

External Ports:

The product provides 2 slots for power boards so that 1 or 2 power modules can be configured as required. If only one power module is configured, a filler panel must be installed in the other slot. AC and DC are incompatible.

Port Name Silk Screen Number of Ports Function
Port Name Silk Screen Number of Ports Function
DC power port – 2 Connects to –48/–60 V DC power.
AC power port – 2 Connects to 110/220 V AC power.
Reset button RESET 1 This button is used to reset the board manually. Resetting the board interrupts the services. Hence, exercise caution when using the reset button.
GPON port PON: 0–15 16 Provides 16 GPON ports for GPON service access.
Upstream port (10GE/GE optical) 10GE/GE: 0–3 4 Provides 4 10GE/GE ports for upstream transmission.
GE maintenance network port ETH 1 10/100/1000M BASE-T maintenance port. Connected to the Ethernet port of the maintenance terminal.
RS-232 serial port/RS-485 monitoring serial port CON/ESC 1 Connected to the serial port of the maintenance terminal/Connected to the serial port of the monitored device.
TOD port TOD 1 Connected to the lower stratum clock.
Environment monitoring port ALM 1 Connected to digital sensors.

MA5801 OLT Product Specifications:

Item Value
Dimensions (W x D x H) (mm) Excluding mounting ears: 442 x 220 x 43.6

Including IEC mounting ears: 482.6 x 220 x 43.6

Including ETSI mounting ears: 531 x 220 x 43.6

Maximum fully-loaded weight 5 kg
Power supply mode
  • DC power supply (dual backup)
  • AC power supply (dual backup)
Working voltage range
  • DC power supply: –38.4 V to –72 V
  • AC power supply: 100 V to 240 V
Rated voltage
  • DC power supply: –48 V/–60 V
  • AC power supply: 110 V/220 V
Maximum input current
  • DC power supply: 6 A
  • AC power supply: 2.5 A
Ambient temperature –40°C to +65°C

The device can start up at a lowest temperature of –25°C.

NOTE:

The +65°C temperature refers to the highest temperature measured at the air intake vent of a service subrack.

Ambient humidity 5%–95% RH
Atmospheric pressure 70–106 kPa

 

Shahed

Hi! I am Shahed Israr. I try to help GPON Technology users with their queries and provide them with relevant and accurate information to the best of my ability. My main goal is to assist and enhance GPON Technology user and help people find the answers they're looking for quickly and easily.

Follow Me:
TwitterFacebookLinkedInPinterestGoogle PlusDiggYouTubeRedditDelicious

Visited 956 times, 1 visit(s) today

Comments

comments

Shahed

Hi! I am Shahed Israr. I try to help GPON Technology users with their queries and provide them with relevant and accurate information to the best of my ability. My main goal is to assist and enhance GPON Technology user and help people find the answers they're looking for quickly and easily.

View all posts by Shahed →

Leave a Reply

Your email address will not be published. Required fields are marked *

Time limit is exhausted. Please reload CAPTCHA.

error: Content is protected !!